Clean ship innovation
Correct & economic application
Continuous support and monitoring
Specifications
Dimensions (W) x (H) x (D) mm
1240 x 2100 x 460 (assembled c/w chemical drums) The instrumentation is housed in a split steel cabinet with hinged lockable doors
The left hand section constructed of stainless steel, houses the sampling system and probes
The right hand section houses signal conditioning, control and the communications interface. |
Probes pH :Range 0 - 14pH Automatic temperature compensation Sealed Reference cell Resolution 0.5% FSD Conductitv :Range 400uMhos (other ranges available) Automatic temperature compensation Resolution 0.5% FSD Dissolved Oxygen :Range 2.5 mg/l Automatic temperature compensation Resolution 0.5% FSD Feed Temperature Stainless steel pocketed probe 0-160?C scaled as 4-20 mA signal |
Flowmeters Mechanical to suit pipe work. OR Ultrasonic Flow Meters (Non penetrating). Clamps onto outside of existing pipe work. Transducer maximum operating temperature 200?C Blowdown Valves Mechanically operated to 32 bar Or Pneumatic, Rated 100 bar to suit application Chemical dosing pumps Air operated 2.1 litre/hr max 500 bar (max) stainless steel Electrically operated diaphragm pump1 litre/hr into 16 bar (max) |
Additional standard features Flushing water system with flow monitoring. Dosing pump manual speed control Dosing pump vent system, returns chemical to drum (No spillage) Fuse failure alarms Auto probe calibration on the unit |